LiXee ZLinky_TIC
| Model | ZLinky_TIC | 
| Vendor | LiXee | 
| Description | Lixee ZLinky | 
| Exposes | ADCO, BASE, OPTARIF, ISOUSC, HCHC, HCHP, BBRHCJW, BBRHPJW, BBRHCJR, BBRHPJR, IINST, IINST2, IINST3, IMAX, IMAX2, IMAX3, PMAX, PAPP, PTEC, DEMAIN, HHPHC, PPOT, PEJP, ADPS, ADIR1, ADIR2, ADIR3, LTARF, NTARF, VTIC, DATE, EASF07, EASF08, EASF09, EASF10, EASD01, EASD02, EASD03, EASD04, EAIT, ERQ1, ERQ2, ERQ3, ERQ4, URMS1, URMS2, URMS3, STGE, PCOUP, SINSTI, SMAXIN, SMAXIN-1, CCASN, CCASN-1, CCAIN, CCAIN-1, UMOY1, UMOY2, UMOY3, SINSTS2, SINSTS3, SMAXN2, SMAXN3, SMAXN-1, SMAXN2-1, SMAXN3-1, MSG1, MSG2, PRM, DPM1, FPM1, DPM2, FPM2, DPM3, FPM3, RELAIS, NJOURF, NJOURF+1, PJOURF+1, PPOINTE1, MOTDETAT, linkquality | 
| Picture | ![]()  | 
    
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
- 
    
measurement_poll_interval: This device does not support reporting electric measurements so it is polled instead. The default poll interval is 60 seconds, set to -1 to disable. The value must be a number with a minimum value of-1 - 
    
linky_mode: Counter with TIC in mode standard or historique. May require restart (default: auto). The value must be one ofauto,historique,standard - 
    
energy_phase: Power with single or three phase. May require restart (default: auto). The value must be one ofauto,single_phase,three_phase - 
    
production: If you produce energy back to the grid (works ONLY when linky_mode: standard, default: auto). The value must be one ofauto,true,false - 
    
tarif: Overrides the automatic current tarif. This option will exclude unnecesary attributes. Open a issue to support more of them. Default: auto. The value must be one ofHistorique - BASE,Historique - HCHP,Historique - EJP,Historique - BBR,Standard - Sem WE Lundi,Standard - Sem WE Mercredi,Standard - Sem WE Vendredi,Standard - BASE,Standard - Heure Pleine Heure Creuse,Standard - TEMPO,auto - 
    
kWh_precision: Number of digits after decimal point for kWh, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 - 
    
measurement_poll_chunk: During the poll, request multiple exposes to the Zlinky at once for reducing Zigbee network overload. Too much request at once could exceed device limit. Requieres Z2M restart. Default: 1. The value must be a number with a minimum value of1 - 
    
tic_command_whitelist: List of TIC commands to be exposed (separated by comma). Reconfigure device after change. Default: all. The value must be textual. 
Exposes
ADCO (text)
Serial Number.
Value can be found in the published state on the meter_serial_number property.
It’s not possible to read (/get) or write (/set) this value.
BASE (numeric)
Base index.
Value can be found in the published state on the current_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
OPTARIF (text)
Tarif option.
Value can be found in the published state on the current_tarif property.
It’s not possible to read (/get) or write (/set) this value.
ISOUSC (numeric)
Subscribed intensity level.
Value can be found in the published state on the available_power property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
HCHC (numeric)
HCHC index.
Value can be found in the published state on the current_tier1_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
HCHP (numeric)
HCHP index.
Value can be found in the published state on the current_tier2_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
BBRHCJW (numeric)
BBRHCJW index.
Value can be found in the published state on the current_tier3_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
BBRHPJW (numeric)
BBRHPJW index.
Value can be found in the published state on the current_tier4_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
BBRHCJR (numeric)
BBRHCJR index.
Value can be found in the published state on the current_tier5_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
BBRHPJR (numeric)
BBRHPJR index.
Value can be found in the published state on the current_tier6_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
IINST (numeric)
RMS current.
Value can be found in the published state on the rms_current property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
IINST2 (numeric)
RMS current (phase 2).
Value can be found in the published state on the rms_current_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
IINST3 (numeric)
RMS current (phase 3).
Value can be found in the published state on the rms_current_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
IMAX (numeric)
RMS current peak.
Value can be found in the published state on the rms_current_max property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
IMAX2 (numeric)
RMS current peak (phase 2).
Value can be found in the published state on the rms_current_max_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
IMAX3 (numeric)
RMS current peak (phase 3).
Value can be found in the published state on the rms_current_max_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
PMAX (numeric)
Three-phase power peak.
Value can be found in the published state on the active_power_max property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is W.
PAPP (numeric)
Apparent power.
Value can be found in the published state on the apparent_power property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
PTEC (text)
Current pricing period.
Value can be found in the published state on the active_register_tier_delivered property.
It’s not possible to read (/get) or write (/set) this value.
DEMAIN (text)
Tomorrow color.
Value can be found in the published state on the tomorrow_color property.
It’s not possible to read (/get) or write (/set) this value.
HHPHC (numeric)
Schedule HPHC.
Value can be found in the published state on the schedule_h_p_h_c property.
It’s not possible to read (/get) or write (/set) this value.
PPOT (numeric)
Presence of potentials.
Value can be found in the published state on the presence_potential property.
It’s not possible to read (/get) or write (/set) this value.
PEJP (numeric)
EJP start notice (30min).
Value can be found in the published state on the start_notice_e_j_p property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is min.
ADPS (numeric)
Subscribed Power Exceeded Warning.
Value can be found in the published state on the warn_d_p_s property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
ADIR1 (numeric)
Over Current Warning (phase 1).
Value can be found in the published state on the warn_d_i_r1 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
ADIR2 (numeric)
Over Current Warning (phase 2).
Value can be found in the published state on the warn_d_i_r2 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
ADIR3 (numeric)
Over Current Warning (phase 3).
Value can be found in the published state on the warn_d_i_r3 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is A.
LTARF (text)
Current supplier price label.
Value can be found in the published state on the current_price property.
It’s not possible to read (/get) or write (/set) this value.
NTARF (numeric)
Current tariff index number.
Value can be found in the published state on the current_index_tarif property.
It’s not possible to read (/get) or write (/set) this value.
VTIC (numeric)
Customer tele-information protocol version.
Value can be found in the published state on the software_revision property.
It’s not possible to read (/get) or write (/set) this value.
DATE (text)
Current date and time.
Value can be found in the published state on the current_date property.
It’s not possible to read (/get) or write (/set) this value.
EASF07 (numeric)
Total provider active power delivered (index 07).
Value can be found in the published state on the current_tier7_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASF08 (numeric)
Total provider active power delivered (index 08).
Value can be found in the published state on the current_tier8_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASF09 (numeric)
Total provider active power delivered (index 09).
Value can be found in the published state on the current_tier9_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASF10 (numeric)
Total provider active power delivered (index 10).
Value can be found in the published state on the current_tier10_summ_delivered property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASD01 (numeric)
Active energy withdrawn Distributor (index 01).
Value can be found in the published state on the active_enerfy_out_d01 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASD02 (numeric)
Active energy withdrawn Distributor (index 02).
Value can be found in the published state on the active_enerfy_out_d02 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASD03 (numeric)
Active energy withdrawn Distributor (index 03).
Value can be found in the published state on the active_enerfy_out_d03 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EASD04 (numeric)
Active energy withdrawn Distributor (index 04).
Value can be found in the published state on the active_enerfy_out_d04 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
EAIT (numeric)
Total active power injected.
Value can be found in the published state on the current_summ_received property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kWh.
ERQ1 (numeric)
Total reactive power (Q1).
Value can be found in the published state on the total_reactive_power property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VArh.
ERQ2 (numeric)
Total reactive power (Q2).
Value can be found in the published state on the reactive_power property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VArh.
ERQ3 (numeric)
Total reactive power (Q3).
Value can be found in the published state on the reactive_power_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VArh.
ERQ4 (numeric)
Total reactive power (Q4).
Value can be found in the published state on the reactive_power_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VArh.
URMS1 (numeric)
RMS voltage.
Value can be found in the published state on the rms_voltage property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
URMS2 (numeric)
RMS voltage (phase 2).
Value can be found in the published state on the rms_voltage_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
URMS3 (numeric)
RMS voltage (phase 3).
Value can be found in the published state on the rms_voltage_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
STGE (text)
Register of Statutes.
Value can be found in the published state on the status_register property.
It’s not possible to read (/get) or write (/set) this value.
PCOUP (numeric)
Apparent power threshold.
Value can be found in the published state on the power_threshold property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is kVA.
SINSTI (numeric)
Instantaneous apparent power injected.
Value can be found in the published state on the injected_v_a property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXIN (numeric)
Apparent power max. injected n.
Value can be found in the published state on the injected_v_a_max_n property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXIN-1 (numeric)
Apparent power max. injected n-1.
Value can be found in the published state on the injected_v_a_max_n1 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
CCASN (numeric)
Current point of the active load curve drawn.
Value can be found in the published state on the active_power property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is W.
CCASN-1 (numeric)
Previous point of the active load curve drawn.
Value can be found in the published state on the active_power_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is W.
CCAIN (numeric)
Point n of the withdrawn active load curve.
Value can be found in the published state on the injected_active_load_n property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is W.
CCAIN-1 (numeric)
Point n-1 of the withdrawn active load curve.
Value can be found in the published state on the injected_active_load_n1 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is W.
UMOY1 (numeric)
Average RMS voltage (phase 1).
Value can be found in the published state on the average_rms_voltage_meas_period property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
UMOY2 (numeric)
Average RMS voltage (phase 2).
Value can be found in the published state on the average_rms_voltage_measure_period_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
UMOY3 (numeric)
Average RMS voltage (phase 3).
Value can be found in the published state on the average_rms_voltage_meas_period_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is V.
SINSTS2 (numeric)
Immediate apparent power delivered (phase 2).
Value can be found in the published state on the apparent_power_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SINSTS3 (numeric)
Immediate apparent power delivered (phase 3).
Value can be found in the published state on the apparent_power_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXN2 (numeric)
Apparent power delivered peak (phase 2).
Value can be found in the published state on the active_power_max_ph_b property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXN3 (numeric)
Apparent power delivered peak (phase 3).
Value can be found in the published state on the active_power_max_ph_c property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXN-1 (numeric)
Apparent power max. draw-off n-1.
Value can be found in the published state on the drawn_v_a_max_n1 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXN2-1 (numeric)
Apparent power max. draw-off n-1 (phase 2).
Value can be found in the published state on the drawn_v_a_max_n1_p2 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
SMAXN3-1 (numeric)
Apparent power max. draw-off n-1 (phase 3).
Value can be found in the published state on the drawn_v_a_max_n1_p3 property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is VA.
MSG1 (text)
Message short.
Value can be found in the published state on the message1 property.
It’s not possible to read (/get) or write (/set) this value.
MSG2 (text)
Message ultra-short.
Value can be found in the published state on the message2 property.
It’s not possible to read (/get) or write (/set) this value.
PRM (text)
PRM number.
Value can be found in the published state on the site_id property.
It’s not possible to read (/get) or write (/set) this value.
DPM1 (numeric)
Start mobile point 1.
Value can be found in the published state on the start_mobile_point1 property.
It’s not possible to read (/get) or write (/set) this value.
FPM1 (numeric)
Stop mobile point 1.
Value can be found in the published state on the stop_mobile_point1 property.
It’s not possible to read (/get) or write (/set) this value.
DPM2 (numeric)
Start mobile point 2.
Value can be found in the published state on the start_mobile_point2 property.
It’s not possible to read (/get) or write (/set) this value.
FPM2 (numeric)
Stop mobile point 2.
Value can be found in the published state on the stop_mobile_point2 property.
It’s not possible to read (/get) or write (/set) this value.
DPM3 (numeric)
Start mobile point 3.
Value can be found in the published state on the start_mobile_point3 property.
It’s not possible to read (/get) or write (/set) this value.
FPM3 (numeric)
Stop mobile point 3.
Value can be found in the published state on the stop_mobile_point3 property.
It’s not possible to read (/get) or write (/set) this value.
RELAIS (numeric)
Value can be found in the published state on the relais property.
It’s not possible to read (/get) or write (/set) this value.
NJOURF (numeric)
Current day number supplier calendar.
Value can be found in the published state on the days_number_current_calendar property.
It’s not possible to read (/get) or write (/set) this value.
NJOURF+1 (numeric)
Next day number supplier calendar.
Value can be found in the published state on the days_number_next_calendar property.
It’s not possible to read (/get) or write (/set) this value.
PJOURF+1 (text)
Profile of the next supplier calendar day.
Value can be found in the published state on the days_profile_current_calendar property.
It’s not possible to read (/get) or write (/set) this value.
PPOINTE1 (text)
Profile of the next check-in day.
Value can be found in the published state on the days_profile_next_calendar property.
It’s not possible to read (/get) or write (/set) this value.
MOTDETAT (text)
Meter Status Word.
Value can be found in the published state on the MOTDETAT property.
It’s not possible to read (/get) or write (/set) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.