Viessmann ZK03840
Model | ZK03840 |
Vendor | Viessmann |
Description | ViCare radiator thermostat valve |
Exposes | climate (occupied_heating_setpoint, local_temperature, system_mode, schedule), window_open, window_open_force, keypad_lockout, battery, linkquality |
Picture |
Notes
Installing the TRV
- install the correct adaptor on the valve
- open cover (push clip on bottom and push front side to slide open)
- insert batteries (
--
should be on the display) - press the button on the top (
--
+((•))
should be on the display) - wait for the device to pair, it took about 2 minutes for me to get the success message in Zigbee2MQTT
- install the TRV on the adaptor (push hard until you feel a click, rotate the TRV until display faces up)
- press the button on the top for 3 seconds (motor will turn,
21°
+((•))
should be on the display) - close the cover
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, schedule
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between7
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:heat
,sleep
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.
Window_open (binary)
Detected by sudden temperature drop or set manually..
Value can be found in the published state on the window_open
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"window_open": ""}
.
It’s not possible to write (/set
) this value.
If value equals true
window_open is ON, if false
OFF.
Window_open_force (binary)
Manually set window_open, ~1 minute to take affect..
Value can be found in the published state on the window_open_force
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"window_open_force": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"window_open_force": NEW_VALUE}
.
If value equals true
window_open_force is ON, if false
OFF.
Keypad_lockout (enum)
Enables/disables physical input on the device.
Value can be found in the published state on the keypad_lockout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
.
The possible values are: unlock
, lock1
, lock2
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.