Siglis ZFP-1A-CH
Model | ZFP-1A-CH |
Vendor | Siglis |
Description | zigfred plus smart in-wall switch |
Exposes | action, linkquality |
Picture |
Options
How to use device type specific configuration
-
front_surface_enabled
: Front Surface LED enabled. The value must be one ofauto
,true
,false
-
dimmer_1_enabled
: Dimmer 1 enabled. The value must be one ofauto
,true
,false
-
dimmer_1_dimming_enabled
: Dimmer 1 dimmable. The value must be one ofauto
,true
,false
-
dimmer_2_enabled
: Dimmer 2 enabled. The value must be one ofauto
,true
,false
-
dimmer_2_dimming_enabled
: Dimmer 2 dimmable. The value must be one ofauto
,true
,false
-
dimmer_3_enabled
: Dimmer 3 enabled. The value must be one ofauto
,true
,false
-
dimmer_3_dimming_enabled
: Dimmer 3 dimmable. The value must be one ofauto
,true
,false
-
dimmer_4_enabled
: Dimmer 4 enabled. The value must be one ofauto
,true
,false
-
dimmer_4_dimming_enabled
: Dimmer 4 dimmable. The value must be one ofauto
,true
,false
-
cover_1_enabled
: Cover 1 enabled. The value must be one ofauto
,true
,false
-
cover_1_tilt_enabled
: Cover 1 tiltable. The value must be one ofauto
,true
,false
-
cover_2_enabled
: Cover 2 enabled. The value must be one ofauto
,true
,false
-
cover_2_tilt_enabled
: Cover 2 tiltable. The value must be one ofauto
,true
,false
-
color_sync
: When enabled colors will be synced, e.g. if the light supports both color x/y and color temperature a conversion from color x/y to color temperature will be done when setting the x/y color (default true). The value must betrue
orfalse
-
transition
: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to0
(no transition). The value must be a number with a minimum value of0
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
invert_cover
: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). The value must betrue
orfalse
Exposes
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: button_1_single
, button_1_double
, button_1_hold
, button_1_release
, button_2_single
, button_2_double
, button_2_hold
, button_2_release
, button_3_single
, button_3_double
, button_3_hold
, button_3_release
, button_4_single
, button_4_double
, button_4_hold
, button_4_release
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.