TuYa X5H-GB-B
Model | X5H-GB-B |
Vendor | TuYa |
Description | Wall-mount thermostat |
Exposes | climate (current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state, preset), sensor, schedule, lock (state), week, brightness_state, sound, frost_protection, factory_reset, heating_temp_limit, deadzone_temperature, upper_temp, linkquality |
Picture | |
White-label | Beok TGR85-ZB |
Exposes
Climate
This climate device supports the following features: current_heating_setpoint
, local_temperature
, local_temperature_calibration
, system_mode
, running_state
, preset
.
current_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"current_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and60
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). Reading (/get
) this attribute is not possible.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. Reading (/get
) this attribute is not possible.preset
: Mode of this device (similar to system_mode). To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"preset": VALUE}
whereVALUE
is one of:manual
,program
. Reading (/get
) this attribute is not possible.running_state
: The current running state. Possible values are:idle
,heat
. Reading (/get
) this attribute is not possible.local_temperature_calibration
: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
The minimal value is-9.9
and the maximum value is9.9
with a step size of0.1
.
Sensor (enum)
Select temperature sensor to use.
Value can be found in the published state on the sensor
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensor": NEW_VALUE}
.
The possible values are: internal
, external
, both
.
Schedule (text)
There are 8 periods in the schedule in total. 6 for workdays and 2 for holidays. It should be set in the following format for each of the periods: hours:minutes/temperature
. All periods should be set at once and delimited by the space symbol. For example: 06:00/20.5 08:00/15 11:30/15 13:30/15 17:00/22 22:00/15 06:00/20 22:00/15
. The thermostat doesn’t report the schedule by itself even if you change it manually from device.
Value can be found in the published state on the schedule
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule": NEW_VALUE}
.
Lock
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
).
To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
.
It’s not possible to read (/get
) this value.
Week (enum)
Week format user for schedule.
Value can be found in the published state on the week
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"week": NEW_VALUE}
.
The possible values are: 5+2
, 6+1
, 7
.
Brightness_state (enum)
Screen brightness.
Value can be found in the published state on the brightness_state
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"brightness_state": NEW_VALUE}
.
The possible values are: off
, low
, medium
, high
.
Sound (binary)
Switches beep sound when interacting with thermostat.
Value can be found in the published state on the sound
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sound": NEW_VALUE}
.
If value equals ON
sound is ON, if OFF
OFF.
Frost_protection (binary)
Antifreeze function.
Value can be found in the published state on the frost_protection
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"frost_protection": NEW_VALUE}
.
If value equals ON
frost_protection is ON, if OFF
OFF.
Factory_reset (binary)
Resets all settings to default. Doesn’t unpair device..
Value can be found in the published state on the factory_reset
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"factory_reset": NEW_VALUE}
.
If value equals ON
factory_reset is ON, if OFF
OFF.
Heating_temp_limit (numeric)
Heating temperature limit.
Value can be found in the published state on the heating_temp_limit
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"heating_temp_limit": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 60
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: default
.
Deadzone_temperature (numeric)
The delta between local_temperature and current_heating_setpoint to trigger Heat.
Value can be found in the published state on the deadzone_temperature
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"deadzone_temperature": NEW_VALUE}
.
The minimal value is 0.5
and the maximum value is 9.5
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: default
.
Upper_temp (numeric)
Value can be found in the published state on the upper_temp
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"upper_temp": NEW_VALUE}
.
The minimal value is 35
and the maximum value is 95
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: default
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.