ShinaSystem USM-300ZB

   
Model USM-300ZB
Vendor ShinaSystem
Description SiHAS multipurpose sensor
Exposes battery, voltage, temperature, humidity, occupancy, illuminance_lux, linkquality
Picture ShinaSystem USM-300ZB

Options

How to use device type specific configuration

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • no_occupancy_since: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a {"no_occupancy_since": 10} will be send after 10 seconds and a {"no_occupancy_since": 60} after 60 seconds. The value must be a list of [object Object].

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Voltage (numeric)

Voltage of the battery in millivolts. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is mV.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is %.

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It’s not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Illuminance_lux (numeric)

Measured illuminance in lux. Value can be found in the published state on the illuminance property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.