TuYa TS0601_smart_CO_air_box
Model | TS0601_smart_CO_air_box |
Vendor | TuYa |
Description | Smart air box (carbon monoxide) |
Exposes | carbon_monoxide, co, linkquality |
Picture |
Options
How to use device type specific configuration
-
co_precision
: Number of digits after decimal point for co, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
co_calibration
: Calibrates the co value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Carbon_monoxide (binary)
Indicates if CO (carbon monoxide) is detected.
Value can be found in the published state on the carbon_monoxide
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
carbon_monoxide is ON, if false
OFF.
Co (numeric)
The measured CO (carbon monoxide) value.
Value can be found in the published state on the co
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is ppm
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.