TuYa TS0601_din_1
Model | TS0601_din_1 |
Vendor | TuYa |
Description | Zigbee DIN energy meter |
Exposes | switch (state), ac_frequency, energy, power, power_factor, voltage, current, produced_energy, linkquality |
Picture | |
White-label | Hiking DDS238-2, TuYa RC-MCB |
Options
How to use device type specific configuration
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Ac_frequency (numeric)
Measured electrical AC frequency.
Value can be found in the published state on the ac_frequency
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is Hz
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Power_factor (numeric)
Instantaneous measured power factor.
Value can be found in the published state on the power_factor
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Produced_energy (numeric)
Sum of produced energy.
Value can be found in the published state on the produced_energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.