TuYa TS0601_cover_6
| Model | TS0601_cover_6 | 
| Vendor | TuYa | 
| Description | Cover motor | 
| Exposes | work_state, cover (state, position), battery, opening_mode, motor_direction, set_upper_limit, factory_reset, linkquality | 
| Picture | ![]()  | 
    
Exposes
Work_state (text)
Value can be found in the published state on the work_state property.
It’s not possible to read (/get) or write (/set) this value.
Cover
The current state of this cover is in the published state under the state property (value is OPEN or CLOSE).
To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "OPEN"}, {"state": "CLOSE"}, {"state": "STOP"}.
It’s not possible to read (/get) this value.
To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"position": VALUE} where VALUE is a number between 0 and 100.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 100.
The unit of this value is %.
Opening_mode (enum)
Opening mode.
Value can be found in the published state on the opening_mode property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"opening_mode": NEW_VALUE}.
The possible values are: tilt, lift.
Motor_direction (enum)
Motor side.
Value can be found in the published state on the motor_direction property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"motor_direction": NEW_VALUE}.
The possible values are: left, right.
Set_upper_limit (enum)
Learning.
Value can be found in the published state on the set_upper_limit property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"set_upper_limit": NEW_VALUE}.
The possible values are: start, stop.
Factory_reset (enum)
Remove limits.
Value can be found in the published state on the factory_reset property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"factory_reset": NEW_VALUE}.
The possible values are: SET.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.