Livolo TI0001-socket
Model | TI0001-socket |
Vendor | Livolo |
Description | Zigbee socket |
Exposes | switch (state), power_on_behavior, linkquality |
Picture |
Notes
After pairing device will be shown as “TI0001” device. Need to manually trigger a re-configure of the device either using web-frontend of Zigbee2MQTT or using MQTT message right after pairing. In case of problems it’s recommended to remove device and than retry pairing and re-configuring device.
Important
These devices can only be used on channel 26. These devices are locked to the manufacturer’s network key (ext_pan_id). Your configuration file data/configuration.yaml must contain the following:
advanced:
ext_pan_id: [33,117,141,25,0,75,18,0]
channel: 26
Therefore these devices may not co-existence with other Zigbee devices. Maybe, you need to add a dedicated coordinator and create a new network for Livolo. If you decided to create a new network, you should specify another ‘pan_id’.
advanced:
pan_id: 6756
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power_on_behavior (enum)
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, on
, toggle
, previous
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.