Sinopé TH1300ZB
Model | TH1300ZB |
Vendor | Sinopé |
Description | Zigbee smart floor heating thermostat |
Exposes | climate (occupied_heating_setpoint, unoccupied_heating_setpoint, local_temperature, system_mode, pi_heating_demand, running_state), thermostat_occupancy, second_display_mode, thermostat_outdoor_temperature, outdoor_temperature_timeout, enable_outdoor_temperature, temperature_display_mode, time_format, backlight_auto_dim, keypad_lockout, power, current, voltage, energy, linkquality |
Picture |
Notes
Pairing
Press the two buttons simultaneously for 3 seconds. The wireless icon will blink when searching for the Zigbee network and stay steady when paired to it. Repeat if unsuccessful.
Unpairing
Press the two buttons simultaneously for 10 seconds and release. The device will restart. The wireless icon will disappear from the display.
The following thermostats parameters can be changed trough MQTT
Occupancy / Unoccupancy
The thermostat can be instructed to use the occupancy or unoccupancy setpoints by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"thermostat_occupancy": "OCCUPANCY"}
where OCCUPANCY
is one of the following values: occupied
, unoccupied
.
The factory default value is occupied
.
Floor control mode
The sensor used by the thermostat for temperature regulation can be changed by publishing
to zigbee2mqtt/FRIENDLY_NAME/set {"floor_control_mode": "SENSOR"}
where SENSOR
is one of the following values: ambiant
, floor
.
The factory default value is floor
.
Ambient maximum heating setpoint
The maximum ambient temperature setpoint of the thermostat can be changed by publishing
to zigbee2mqtt/FRIENDLY_NAME/set {"ambiant_max_heat_setpoint": "TEMPERATURE"}
where TEMPERATURE
is the desired value (between 5 and 36 Celcius).
This feature is disabled by default.
Floor minimum heating setpoint
The minimum floor temperature setpoint of the thermostat can be changed by publishing
to zigbee2mqtt/FRIENDLY_NAME/set {"floor_min_heat_setpoint": "TEMPERATURE"}
where TEMPERATURE
is the desired value (between 5 and 36 Celcius).
This feature is disabled by default.
Floor maximum heating setpoint
The maximum floor temperature setpoint of the thermostat can be changed by publishing
to zigbee2mqtt/FRIENDLY_NAME/set {"floor_max_heat_setpoint": "TEMPERATURE"}
where TEMPERATURE
is the desired value (between 5 and 36 Celcius).
This feature is disabled by default.
Floor temperature sensor
The floor thermistor temperature sensor value connected to the thermostat can be changed by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"temperature_sensor": "SENSOR"}
where SENSOR
is one of the following values: 10k
, 12k
.
The factory default value is 10k
.
Display backlight
The thermostat display can be set to turn on only when a button is pressed or stay on and auto dim by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"backlight_auto_dim": "BACKLIGHT"}
where BACKLIGHT
is one of the following values: on demand
, sensing
.
The factory default value is sensing
.
Time to display
The time clock value to display on the thermostat can be set by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"thermostat_time": "TIME"}
where TIME
is the number of seconds since 2000-01-01 or empty.
The Zigbee gateway local time will be used when publishing an empty value.
By default, the time clock is not displayed.
Time format displayed
The time clock format on the thermostat display can be changed by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"time_format": "FORMAT"}
where FORMAT
is one of the following values: 12h
, 24h
.
The factory default value is 24h
.
Enable outdoor temperature display
The display of outdoor temperature on the thermostat can be enabled / disabled by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"enable_outdoor_temperature": "ENABLE"}
where ENABLE
is one of the following values: on
, off
.
on
value will set the outdoor temperature refresh timeout to 3 hours.
off
value will set the outdoor temperature refresh timeout to 30 seconds.
When the refresh timeout is expired the thermostat setpoint temperature will be displayed.
The outdoor temperature is not displayed by default.
Outdoor temperature to display
The outdoor temperature to display on the thermostat can be changed by
publishing to zigbee2mqtt/FRIENDLY_NAME/set {"thermostat_outdoor_temperature": "TEMPERATURE"}
where TEMPERATURE
is between -100 to +100.
The following status are reported by the thermostat
Groud fault circuit indicator status (GFCi)
Turns on
when the thermostat GFCi detects a ground fault. The status is reported
to the device state as gfci_status
every hour or when it changes.
gfci_status
has one of the following values: on
, off
.
The default value is off
.
Floor limit status
This status is on
when the floor temperature exceeds the maximum floor heating setpoint.
It is reported to the device state as floor_limit_status
every hour or when it changes.
floor_limit_status
has one of the following values: on
, off
.
The default value is off
.
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, unoccupied_heating_setpoint
, local_temperature
, system_mode
, pi_heating_demand
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and36
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.pi_heating_demand
: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"pi_heating_demand": VALUE}
whereVALUE
is the % between0
and100
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of the thermostat. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. Reading (/get
) this attribute is not possible.
Thermostat_occupancy (enum)
Occupancy state of the thermostat.
Value can be found in the published state on the thermostat_occupancy
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_occupancy": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_occupancy": NEW_VALUE}
.
The possible values are: unoccupied
, occupied
.
Second_display_mode (enum)
Displays the outdoor temperature and then returns to the set point in “auto” mode, or clears in “outdoor temp” mode when expired..
Value can be found in the published state on the second_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"second_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"second_display_mode": NEW_VALUE}
.
The possible values are: auto
, setpoint
, outdoor temp
.
Thermostat_outdoor_temperature (numeric)
Outdoor temperature for the secondary display.
Value can be found in the published state on the thermostat_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_outdoor_temperature": NEW_VALUE}
.
The minimal value is -99.5
and the maximum value is 99.5
.
The unit of this value is °C
.
Outdoor_temperature_timeout (numeric)
Time in seconds after which the outdoor temperature is considered to have expired.
Value can be found in the published state on the outdoor_temperature_timeout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"outdoor_temperature_timeout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"outdoor_temperature_timeout": NEW_VALUE}
.
The minimal value is 30
and the maximum value is 64800
.
The unit of this value is Seconds
.
Besides the numeric values the following values are accepected: 15 min
, 30 min
, 1 hour
.
Enable_outdoor_temperature (binary)
DEPRECATED: Use second_display_mode or control via outdoor_temperature_timeout.
Value can be found in the published state on the enable_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"enable_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"enable_outdoor_temperature": NEW_VALUE}
.
If value equals ON
enable_outdoor_temperature is ON, if OFF
OFF.
Temperature_display_mode (enum)
The temperature format displayed on the thermostat screen.
Value can be found in the published state on the temperature_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_display_mode": NEW_VALUE}
.
The possible values are: celsius
, fahrenheit
.
Time_format (enum)
The time format featured on the thermostat display.
Value can be found in the published state on the time_format
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"time_format": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"time_format": NEW_VALUE}
.
The possible values are: 24h
, 12h
.
Backlight_auto_dim (enum)
Control backlight dimming behavior.
Value can be found in the published state on the backlight_auto_dim
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"backlight_auto_dim": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"backlight_auto_dim": NEW_VALUE}
.
The possible values are: on_demand
, sensing
.
Keypad_lockout (enum)
Enables or disables the device’s buttons.
Value can be found in the published state on the keypad_lockout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
.
The possible values are: unlock
, lock1
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.