TERNCY TERNCY-PP01
Model | TERNCY-PP01 |
Vendor | TERNCY |
Description | Awareness switch |
Exposes | temperature, occupancy, illuminance_lux, illuminance, action, linkquality |
Picture |
Notes
Deprecated click event
By default this device exposes a deprecated click
event. It’s recommended to use the action
event instead.
To disable the click
event, set legacy: false
for this device in configuration.yaml
. Example:
devices:
'0x12345678':
friendly_name: my_device
legacy: false
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
occupancy_timeout
: Time in seconds after which occupancy is cleared after detecting it (default 90 seconds). The value must be a number with a minimum value of0
-
no_occupancy_since
: Sends a message the last time occupancy (occupancy: true) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object]. -
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Illuminance_lux (numeric)
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It’s not possible to read (/get
) or write (/set
) this value.
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: single
, double
, triple
, quadruple
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.