Nous SZ-T04
Model | SZ-T04 |
Vendor | Nous |
Description | Temperature and humidity sensor with clock |
Exposes | temperature, humidity, battery, temperature_report_interval, humidity_report_interval, temperature_unit_convert, temperature_alarm, max_temperature, min_temperature, temperature_sensitivity, humidity_alarm, max_humidity, min_humidity, humidity_sensitivity, linkquality |
Picture |
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Temperature_report_interval (numeric)
Temperature Report interval.
Value can be found in the published state on the temperature_report_interval
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_report_interval": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 120
.
The unit of this value is min
.
Humidity_report_interval (numeric)
Humidity Report interval.
Value can be found in the published state on the humidity_report_interval
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_report_interval": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 120
.
The unit of this value is min
.
Temperature_unit_convert (enum)
Current display unit.
Value can be found in the published state on the temperature_unit_convert
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_unit_convert": NEW_VALUE}
.
The possible values are: celsius
, fahrenheit
.
Temperature_alarm (enum)
Temperature alarm status.
Value can be found in the published state on the temperature_alarm
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: canceled
, lower_alarm
, upper_alarm
.
Max_temperature (numeric)
Alarm temperature max.
Value can be found in the published state on the max_temperature
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_temperature": NEW_VALUE}
.
The minimal value is -20
and the maximum value is 60
.
The unit of this value is °C
.
Min_temperature (numeric)
Alarm temperature min.
Value can be found in the published state on the min_temperature
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_temperature": NEW_VALUE}
.
The minimal value is -20
and the maximum value is 60
.
The unit of this value is °C
.
Temperature_sensitivity (numeric)
Temperature sensitivity.
Value can be found in the published state on the temperature_sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_sensitivity": NEW_VALUE}
.
The minimal value is 0.1
and the maximum value is 50
.
The unit of this value is °C
.
Humidity_alarm (enum)
Humidity alarm status.
Value can be found in the published state on the humidity_alarm
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: canceled
, lower_alarm
, upper_alarm
.
Max_humidity (numeric)
Alarm humidity max.
Value can be found in the published state on the max_humidity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_humidity": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Min_humidity (numeric)
Alarm humidity min.
Value can be found in the published state on the min_humidity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_humidity": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Humidity_sensitivity (numeric)
Humidity sensitivity.
Value can be found in the published state on the humidity_sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_sensitivity": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 100
.
The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.