Climax SRAC-23B-ZBSR
| Model | SRAC-23B-ZBSR | 
| Vendor | Climax | 
| Description | Smart siren | 
| Exposes | battery_low, tamper, warning, squawk, max_duration, alarm, linkquality | 
| Picture | ![]()  | 
    
Notes
Warning usage
Warning only support a single mode, burglar
Duration of using warning can be shorter than max_duration but not longer. If max_duration are set to 60 seconds, and you try to set warning with duration of 90 seconds, the warning will only apply for 60 seconds. Default value of max_duration are 300 seconds
This device do not support the strobe_duty_cycle functionality
Triggering alarm, Advanced
This siren can be triggered manually by publishing to zigbee2mqtt/FRIENDLY_NAME/set with the payloads:
To start :
{"warning":{"duration":60,"level":"low","mode":"burglar","strobe":false,"strobe_duty_cycle":0}}Where:duration: the number of seconds the alarm will be onlevel:low,medium,high,very_highmode:stop,burglarstrobe:true,falsestrobe_duty_cycle: not supported
To stop:
{"warning":{"duration":60,"level":"low","mode":"stop","strobe":false,"strobe_duty_cycle":0}}
Triggering alarm, Simple
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm": "START"} and {"alarm": "OFF"}
Set max_duration from the Zigbee2MQTT UI or by publishing {"max_duration": NEW_VALUE}
This alarm are preset to highest volume
Exposes
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low property.
It’s not possible to read (/get) or write (/set) this value.
If value equals true battery_low is ON, if false OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper property.
It’s not possible to read (/get) or write (/set) this value.
If value equals true tamper is ON, if false OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode(enum): Mode of the warning (sound effect) allowed values:stop,burglar,fire,emergency,police_panic,fire_panic,emergency_paniclevel(enum): Sound level allowed values:low,medium,high,very_highstrobe_level(enum): Intensity of the strobe allowed values:low,medium,high,very_highstrobe(binary): Turn on/off the strobe (light) during warning allowed values:trueorfalsestrobe_duty_cycle(numeric): Length of the flash cycle max value is 10duration(numeric): Duration in seconds of the alarm unit is s
Squawk (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"squawk": {"state": VALUE, "level": VALUE, "strobe": VALUE}}
state(enum): Set Squawk state allowed values:system_is_armed,system_is_disarmedlevel(enum): Sound level allowed values:low,medium,high,very_highstrobe(binary): Turn on/off the strobe (light) for Squawk allowed values:trueorfalse
Max_duration (numeric)
Duration of Siren.
Value can be found in the published state on the max_duration property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"max_duration": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_duration": NEW_VALUE}.
The minimal value is 0 and the maximum value is 600.
The unit of this value is s.
Alarm (binary)
Manual start of siren.
Value will not be published in the state.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm": NEW_VALUE}.
If value equals START alarm is ON, if OFF OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.