Xiaomi SP-EUC01

   
Model SP-EUC01
Vendor Xiaomi
Description Aqara EU smart plug
Exposes switch (state), power, energy, power_outage_memory, voltage, current, device_temperature, consumer_connected, led_disabled_night, overload_protection, auto_off, button_lock, linkquality
Picture Xiaomi SP-EUC01

Notes

Issues with inadvertent state toggling by control switches

It’s been reported by several people that this plug can be turned on or off by control switches (e.g. IKEA E1812 or E1743) when routed through this plug. The problem only affects firmware version v42 according to current knowledge. A temporary solution is currently to install an older firmware version (v32) with a modified file version header to bypass the downgrade restriction. See issue #13903 for a tutorial and further information.

Pairing

Press and hold the button on the device for +- 5 seconds, until the blue light starts blinking.

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.

  • current_precision: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • device_temperature_calibration: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Power_outage_memory (binary)

Enable/disable the power outage memory, this recovers the on/off mode after power failure. Value can be found in the published state on the power_outage_memory property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_outage_memory": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_outage_memory": NEW_VALUE}. If value equals true power_outage_memory is ON, if false OFF.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is A.

Device_temperature (numeric)

Device temperature (polled every 30 min). Value can be found in the published state on the device_temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Consumer_connected (binary)

Indicates whether a plug is physically attached. Device does not have to pull power or even be connected electrically (state of this binary switch can be ON even if main power switch is OFF). Value can be found in the published state on the consumer_connected property. It’s not possible to read (/get) or write (/set) this value. If value equals true consumer_connected is ON, if false OFF.

Led_disabled_night (binary)

Enable/disable the LED at night. Value can be found in the published state on the led_disabled_night property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_disabled_night": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_disabled_night": NEW_VALUE}. If value equals true led_disabled_night is ON, if false OFF.

Overload_protection (numeric)

Maximum allowed load, turns off if exceeded. Value can be found in the published state on the overload_protection property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"overload_protection": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"overload_protection": NEW_VALUE}. The minimal value is 100 and the maximum value is 2300. The unit of this value is W.

Auto_off (binary)

Turn the device automatically off when attached device consumes less than 2W for 20 minutes. Value can be found in the published state on the auto_off property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"auto_off": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"auto_off": NEW_VALUE}. If value equals true auto_off is ON, if false OFF.

Button_lock (binary)

Disables the physical switch button. Value can be found in the published state on the button_lock property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"button_lock": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"button_lock": NEW_VALUE}. If value equals ON button_lock is ON, if OFF OFF.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.