Ubisys S2
Model | S2 |
Vendor | Ubisys |
Description | Power switch S2 |
Exposes | switch (state), action, power_on_behavior, power, energy, linkquality |
Picture |
Notes
Configuring Inputs
In case the input(s) need to be reconfigured (e.g. to use stationary switches instead of momentary ones or vice versa) this can be done in the same way as it is being done for the ubisys C4.
(Re-)Binding and/or Decoupling
Also see the ubisys C4 documentation, example use cases:
- Use the second input to control a different Zigbee device (S1-R only, S1 only has one input)
- Completely decouple the input(s) from the local load
When decoupled, ‘action’ will be published when pressing the attached switch button.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number. -
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:simulated_brightness: delta: 20 # delta per interval, default = 20 interval: 200 # interval in milliseconds, default = 200
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
Switch (l2 endpoint)
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l2": ""}
.
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: toggle_s1
, toggle_s2
, on_s1
, on_s2
, off_s1
, off_s2
, recall_*_s1
, recal_*_s2
, brightness_move_up_s1
, brightness_move_up_s2
, brightness_move_down_s1
, brightness_move_down_s2
, brightness_stop_s1
, brightness_stop_s2
.
Power_on_behavior (enum, l1 endpoint)
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior_l1
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior_l1": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior_l1": NEW_VALUE}
.
The possible values are: off
, previous
, on
.
Power_on_behavior (enum, l2 endpoint)
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior_l2
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior_l2": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior_l2": NEW_VALUE}
.
The possible values are: off
, previous
, on
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"energy": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.