Climax PRL-1ZBS-12/24V
Model | PRL-1ZBS-12/24V |
Vendor | Climax |
Description | Zigbee 12-24V relay controller |
Exposes | switch (state), power_on_behavior, linkquality |
Picture |
Notes
Calibration
- Befor calibration, the external local switches must be connected to the Shutter Control.
- Press and hold the Function button for 3~10 seconds and release to enter Calubration mode. The Shutter Controller will roll toward the “Open” direction for 4 minutes upon entering Calibration mode.
- Wait for 4 minutes for Shutter Control to stop rolling to “Open” direction, then activate the connected external local “Close” switch to close the shutter.
- Activate the “Open” external local switch the moment the shutter is fully closed. The Shutter controll will record to time it took between step 3 and 4 as the new “close time”
- The Shutter control will roll toward open direction after step 4
- Activate the “Close” external local switch the moment the shutter is fully opended. The Shutter controll will record to time it took between step 5 and 6 as the new “open time”
Options
How to use device type specific configuration
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power_on_behavior (enum)
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, on
, toggle
, previous
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.