OWON PCT504
Model | PCT504 |
Vendor | OWON |
Description | HVAC fan coil |
Exposes | humidity, occupancy, climate (system_mode, local_temperature, running_mode, running_state, occupied_heating_setpoint, unoccupied_heating_setpoint, occupied_cooling_setpoint, unoccupied_cooling_setpoint), fan (state, mode), programming_operation_mode, keypad_lockout, max_heat_setpoint_limit, min_heat_setpoint_limit, max_cool_setpoint_limit, min_cool_setpoint_limit, linkquality |
Picture |
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object]. -
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Climate
This climate device supports the following features: system_mode
, local_temperature
, running_mode
, running_state
, occupied_heating_setpoint
, unoccupied_heating_setpoint
, occupied_cooling_setpoint
, unoccupied_cooling_setpoint
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.occupied_cooling_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_cooling_setpoint": VALUE}
whereVALUE
is the °C between7
and35
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_cooling_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
,cool
,fan_only
,sleep
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
,cool
,fan_only
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.
Fan
The current state of this fan is in the published state under the fan_state
property (value is ON
or OFF
).
To control this fan publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"fan_state": "ON"}
or {"fan_state": "OFF"}
.
To read the current state of this fan publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"fan_state": ""}
.
To change the mode publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"fan_mode": VALUE}
where VALUE
can be: low
, medium
, high
, on
, auto
.
Programming_operation_mode (enum)
Controls how programming affects the thermostat. Possible values: setpoint (only use specified setpoint), schedule (follow programmed setpoint schedule), schedule_with_preheat (follow programmed setpoint schedule with pre-heating). Changing this value does not clear programmed schedules..
Value can be found in the published state on the programming_operation_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"programming_operation_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"programming_operation_mode": NEW_VALUE}
.
The possible values are: setpoint
, schedule
, schedule_with_preheat
, eco
.
Keypad_lockout (enum)
Enables/disables physical input on the device.
Value can be found in the published state on the keypad_lockout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
.
The possible values are: unlock
, lock1
, lock2
.
Max_heat_setpoint_limit (numeric)
Maximum Heating set point limit.
Value can be found in the published state on the max_heat_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_heat_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_heat_setpoint_limit": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 30
.
The unit of this value is °C
.
Min_heat_setpoint_limit (numeric)
Minimum Heating set point limit.
Value can be found in the published state on the min_heat_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"min_heat_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_heat_setpoint_limit": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 30
.
The unit of this value is °C
.
Max_cool_setpoint_limit (numeric)
Maximum Cooling set point limit.
Value can be found in the published state on the max_cool_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_cool_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_cool_setpoint_limit": NEW_VALUE}
.
The minimal value is 7
and the maximum value is 35
.
The unit of this value is °C
.
Min_cool_setpoint_limit (numeric)
Minimum Cooling point limit.
Value can be found in the published state on the min_cool_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"min_cool_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_cool_setpoint_limit": NEW_VALUE}
.
The minimal value is 7
and the maximum value is 35
.
The unit of this value is °C
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.