TuYa MIR-HE200-TY
Model | MIR-HE200-TY |
Vendor | TuYa |
Description | Human presence sensor with fall function |
Exposes | illuminance_lux, presence, occupancy, motion_speed, motion_direction, radar_sensitivity, radar_scene, tumble_switch, fall_sensitivity, tumble_alarm_time, fall_down_status, static_dwell_alarm, linkquality |
Picture |
Notes
Pairing
Factory resetting by pushing the “Reset-Button” longer than 5 seconds or by using Touchlink factory reset.
Exposes
Illuminance_lux (numeric)
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Presence (binary)
Indicates whether the device detected presence.
Value can be found in the published state on the presence
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
presence is ON, if false
OFF.
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Motion_speed (numeric)
Speed of movement.
Value can be found in the published state on the motion_speed
property.
It’s not possible to read (/get
) or write (/set
) this value.
Motion_direction (enum)
direction of movement from the point of view of the radar.
Value can be found in the published state on the motion_direction
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: standing_still
, moving_forward
, moving_backward
.
Radar_sensitivity (numeric)
Sensitivity of the radar.
Value can be found in the published state on the radar_sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"radar_sensitivity": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 10
.
Radar_scene (enum)
Presets for sensitivity for presence and movement.
Value can be found in the published state on the radar_scene
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"radar_scene": NEW_VALUE}
.
The possible values are: default
, area
, toilet
, bedroom
, parlour
, office
, hotel
.
Tumble_switch (enum)
Tumble status switch.
Value can be found in the published state on the tumble_switch
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"tumble_switch": NEW_VALUE}
.
The possible values are: ON
, OFF
.
Fall_sensitivity (numeric)
Fall sensitivity of the radar.
Value can be found in the published state on the fall_sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"fall_sensitivity": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 10
.
Tumble_alarm_time (numeric)
Tumble alarm time.
Value can be found in the published state on the tumble_alarm_time
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"tumble_alarm_time": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 5
.
The unit of this value is min
.
Fall_down_status (enum)
Fall down status.
Value can be found in the published state on the fall_down_status
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: none
, maybe_fall
, fall
.
Static_dwell_alarm (text)
Static dwell alarm.
Value can be found in the published state on the static_dwell_alarm
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.