Xiaomi MCCGQ11LM
Model | MCCGQ11LM |
Vendor | Xiaomi |
Description | Aqara door & window contact sensor |
Exposes | battery, contact, device_temperature, voltage, power_outage_count, linkquality |
Picture |
Notes
Battery
Uses a CR1632 battery
Pairing
Press and hold the reset button on the device for +- 5 seconds (until the blue light starts blinking).
After this the device will automatically join.
If this doesn’t work, after starting the pairing process with the long press, keep short pressing the button aprroximately once a second until the interview process is finished.
Troubleshooting: device stops sending messages/disconnects from network
Since Xiaomi devices do not fully comply to the Zigbee standard, it sometimes happens that they disconnect from the network. Most of the times this happens because of the following reasons:
- Device has a weak signal, you can see the signal quality in the published messages as
linkquality
. A linkquality < 20 is considered weak. - Low battery voltage, this can even happen when the battery still appears full. Try a different battery.
- The device is connected through a router which cannot deal with Xiaomi devices. This is known to happen devices from: Centralite, General Electric, Iris, Ledvance, Legrand, OSRAM, Sylvania, SmartThings, Securifi. A possible solution is to connect the device directly to the central coordinator by pushing the reset button while being physically close to it.
More detailed information about this can be found here.
Recommendation
If the contact is being made via a horizontal slide (e.g. the sensor is placed at the top of a sliding door), the sensor may provide three or more messages with conflicting states. To get around this issue, consider using the debounce
option in your device specific configuration.
E.g. (devices.yaml)
'0xabc457fffe679xyz':
friendly_name: my_sensor
debounce: 1
Options
How to use device type specific configuration
device_temperature_calibration
: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Contact (binary)
Indicates if the contact is closed (= true) or open (= false).
Value can be found in the published state on the contact
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals false
contact is ON, if true
OFF.
Device_temperature (numeric)
Temperature of the device.
Value can be found in the published state on the device_temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Power_outage_count (numeric)
Number of power outages.
Value can be found in the published state on the power_outage_count
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.