CTM Lyng MBD-S

   
Model MBD-S
Vendor CTM Lyng
Description MBD-S, motion detector with 16A relay
Exposes switch (state), illuminance, illuminance_lux, occupancy, device_enabled, linkquality
Picture CTM Lyng MBD-S

Options

How to use device type specific configuration

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

  • no_occupancy_since: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a {"no_occupancy_since": 10} will be send after 10 seconds and a {"no_occupancy_since": 60} after 60 seconds. The value must be a list of [object Object].

Exposes

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It’s not possible to read (/get) or write (/set) this value.

Illuminance_lux (numeric)

Measured illuminance in lux. Value can be found in the published state on the illuminance_lux property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It’s not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Device_enabled (binary)

Turn the device on or off. Value can be found in the published state on the device_enabled property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"device_enabled": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"device_enabled": NEW_VALUE}. If value equals ON device_enabled is ON, if OFF OFF.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.