Xiaomi JTQJ-BF-01LM/BW
Model | JTQJ-BF-01LM/BW |
Vendor | Xiaomi |
Description | MiJia gas leak detector |
Exposes | gas, battery_low, tamper, sensitivity, gas_density, selftest, linkquality |
Picture | |
White-label | Xiaomi YTC4019RT |
Notes
Pairing
Plug the device in and wait for around 5mins, while it performs its self-tests. A successful self-test is indicated by couple of beeps and a steady green led. Now the device is ready for pairing. To initiate pairing quickly press the button three times in a row.
Sensitivity
The sensitivity can be changed by publishing to zigbee2mqtt/FRIENDLY_NAME/set
{"sensitivity": "SENSITIVITY"}
where SENSITIVITY
is one of the following
values: low
, medium
, high
.
Self-test
A self-test can be trigged by publishing to zigbee2mqtt/FRIENDLY_NAME/set
{"selftest": ""}
.
If the selftest is executed successfully you will hear the device beep in 30 seconds.
Exposes
Gas (binary)
Indicates whether the device detected gas.
Value can be found in the published state on the gas
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
gas is ON, if false
OFF.
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Sensitivity (enum)
Value can be found in the published state on the sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensitivity": NEW_VALUE}
.
The possible values are: low
, medium
, high
.
Gas_density (numeric)
Value can be found in the published state on the gas_density
property.
It’s not possible to read (/get
) or write (/set
) this value.
Selftest (enum)
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"selftest": NEW_VALUE}
.
The possible values are: ``.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.