Datek HSE2905E
Model | HSE2905E |
Vendor | Datek |
Description | Datek Eva AMS HAN power-meter sensor |
Exposes | power, energy, current, voltage, current_phase_b, voltage_phase_b, current_phase_c, voltage_phase_c, temperature, linkquality |
Picture |
Notes
Pairing
Factory reset by removing the plastic cover and press & hold the power button for 10 seconds. The LED is then starting to blink Red/Blue to indicate in pairing mode.
Should automatically support (only tested Kamstrup)
- Aidon
- Kaifa
- Kamstrup
Configuring interface mode
There should be no need to configure into any interface mode as the Eva HAN should autodetect the correct mode.
Not getting measurements
In case you are not getting any measurements, it could be that your firmware is too old. If firmware are < 0.4 either update fw via Eva Smart HUB or ask Datek for a replacement with min fw 0.4. Tested on 0.4.
Where do I find this product
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Current_phase_b (numeric)
Instantaneous measured electrical current on phase B.
Value can be found in the published state on the current_phase_b
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage_phase_b (numeric)
Measured electrical potential value on phase B.
Value can be found in the published state on the voltage_phase_b
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Current_phase_c (numeric)
Instantaneous measured electrical current on phase C.
Value can be found in the published state on the current_phase_c
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage_phase_c (numeric)
Measured electrical potential value on phase C.
Value can be found in the published state on the voltage_phase_c
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.