Evanell EZ200
Model | EZ200 |
Vendor | Evanell |
Description | Thermostatic radiator valve |
Exposes | lock (state), battery, climate (current_heating_setpoint, local_temperature, system_mode), linkquality |
Picture |
Notes
Pairing
Remove batteries. Put battery back in, holding the middle button for 5s. Three horizontal lines flash. Push the “up” button. Device should now enter pairing mode (Wifi-symbol flashes).
Exposes
Lock
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
).
To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
.
It’s not possible to read (/get
) this value.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Climate
This climate device supports the following features: current_heating_setpoint
, local_temperature
, system_mode
.
current_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"current_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). Reading (/get
) this attribute is not possible.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
,auto
. Reading (/get
) this attribute is not possible.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.