Schneider Electric EKO07259

   
Model EKO07259
Vendor Schneider Electric
Description Smart thermostat
Exposes keypad_lockout, schneider_pilot_mode, temperature_display_mode, climate (occupied_heating_setpoint, local_temperature, system_mode, running_state, pi_heating_demand), linkquality
Picture Schneider Electric EKO07259

Options

How to use device type specific configuration

  • thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one of celsius, fahrenheit

Exposes

Keypad_lockout (binary)

Enables/disables physical input on the device. Value can be found in the published state on the keypad_lockout property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"keypad_lockout": NEW_VALUE}. If value equals lock1 keypad_lockout is ON, if unlock OFF.

Schneider_pilot_mode (enum)

Controls piloting mode. Value can be found in the published state on the schneider_pilot_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"schneider_pilot_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"schneider_pilot_mode": NEW_VALUE}. The possible values are: contactor, pilot.

Temperature_display_mode (enum)

The temperature format displayed on the thermostat screen. Value can be found in the published state on the temperature_display_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_display_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_display_mode": NEW_VALUE}. The possible values are: celsius, fahrenheit.

Climate

This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode, running_state, pi_heating_demand.

  • occupied_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_heating_setpoint": VALUE} where VALUE is the °C between 4 and 30. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_heating_setpoint": ""}.
  • pi_heating_demand: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"pi_heating_demand": VALUE} where VALUE is the % between 0 and 100. Reading (/get) this attribute is not possible.
  • local_temperature: Current temperature measured on the device (in °C). To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: off, heat. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"system_mode": ""}.
  • running_state: The current running state. Possible values are: idle, heat. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"running_state": ""}.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.