Custom devices (DiY) EFEKTA_eFlower_Pro

   
Model EFEKTA_eFlower_Pro
Vendor Custom devices (DiY)
Description Plant Wattering Sensor with e-ink display 2.13
Exposes soil_moisture, battery, illuminance, temperature, humidity, linkquality
Picture Custom devices (DiY) EFEKTA_eFlower_Pro

Options

How to use device type specific configuration

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

  • soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Soil_moisture (numeric)

Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is %.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It’s not possible to read (/get) or write (/set) this value.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is %.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.