EARU EAKCB-T-M-Z
Model | EAKCB-T-M-Z |
Vendor | EARU |
Description | Smart circuit breaker |
Exposes | switch (state), power_outage_memory, indicator_mode, power, current, voltage, energy, temperature, temperature_threshold, temperature_breaker, power_threshold, power_breaker, over_current_threshold, over_current_breaker, over_voltage_threshold, over_voltage_breaker, under_voltage_threshold, under_voltage_breaker, linkquality |
Picture |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power_outage_memory (enum)
Recover state after power outage.
Value can be found in the published state on the power_outage_memory
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_outage_memory": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_outage_memory": NEW_VALUE}
.
The possible values are: on
, off
, restore
.
Indicator_mode (enum)
LED indicator mode.
Value can be found in the published state on the indicator_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"indicator_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"indicator_mode": NEW_VALUE}
.
The possible values are: off
, off/on
, on/off
, on
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Temperature_threshold (numeric)
High temperature threshold.
Value can be found in the published state on the temperature_threshold
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_threshold": NEW_VALUE}
.
The minimal value is 40
and the maximum value is 100
.
The unit of this value is *C
.
Temperature_breaker (binary)
High temperature breaker.
Value can be found in the published state on the temperature_breaker
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_breaker": NEW_VALUE}
.
If value equals ON
temperature_breaker is ON, if OFF
OFF.
Power_threshold (numeric)
High power threshold.
Value can be found in the published state on the power_threshold
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_threshold": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 26
.
The unit of this value is kW
.
Power_breaker (binary)
High power breaker.
Value can be found in the published state on the power_breaker
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_breaker": NEW_VALUE}
.
If value equals ON
power_breaker is ON, if OFF
OFF.
Over_current_threshold (numeric)
Over-current threshold.
Value can be found in the published state on the over_current_threshold
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_current_threshold": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 64
.
The unit of this value is A
.
Over_current_breaker (binary)
Over-current breaker.
Value can be found in the published state on the over_current_breaker
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_current_breaker": NEW_VALUE}
.
If value equals ON
over_current_breaker is ON, if OFF
OFF.
Over_voltage_threshold (numeric)
Over-voltage threshold.
Value can be found in the published state on the over_voltage_threshold
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_voltage_threshold": NEW_VALUE}
.
The minimal value is 220
and the maximum value is 260
.
The unit of this value is V
.
Over_voltage_breaker (binary)
Over-voltage breaker.
Value can be found in the published state on the over_voltage_breaker
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_voltage_breaker": NEW_VALUE}
.
If value equals ON
over_voltage_breaker is ON, if OFF
OFF.
Under_voltage_threshold (numeric)
Under-voltage threshold.
Value can be found in the published state on the under_voltage_threshold
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"under_voltage_threshold": NEW_VALUE}
.
The minimal value is 76
and the maximum value is 240
.
The unit of this value is V
.
Under_voltage_breaker (binary)
Under-voltage breaker.
Value can be found in the published state on the under_voltage_breaker
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"under_voltage_breaker": NEW_VALUE}
.
If value equals ON
under_voltage_breaker is ON, if OFF
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.