IKEA E1525/E1745
Model | E1525/E1745 |
Vendor | IKEA |
Description | TRADFRI motion sensor |
Exposes | battery, occupancy, requested_brightness_level, requested_brightness_percent, illuminance_above_threshold, linkquality |
Picture |
Notes
Pairing
Pair the sensor to Zigbee2MQTT by pressing the pair button 4 times in a row. The red light on the front side should flash a few times and then turn off. After a few seconds it turns back on and pulsate. When connected, the light turns off.
Binding
The E1745 can be bound to groups. Although it is not possible to set the groupID at which the E1745 sends messages. But you can watch out in the log files for following debug messages:
debug Received Zigbee message from 'device', type 'commandOnWithTimedOff', cluster 'genOnOff', data '{"ctrlbits":0,"offwaittime":0,"ontime":600}' from endpoint 1 with groupID 123
Now you can create a group with a groupID of 123 and add yur devices that should receive the message.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
occupancy_timeout
: Time in seconds after which occupancy is cleared after detecting it (default 90 seconds). The value must be a number with a minimum value of0
-
illuminance_below_threshold_check
: Set to false to also send messages when illuminance is above threshold in night mode (default true). The value must betrue
orfalse
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Requested_brightness_level (numeric)
Value can be found in the published state on the requested_brightness_level
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 76
and the maximum value is 254
.
Requested_brightness_percent (numeric)
Value can be found in the published state on the requested_brightness_percent
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 30
and the maximum value is 100
.
Illuminance_above_threshold (binary)
Indicates whether the device detected bright light (works only in night mode).
Value can be found in the published state on the illuminance_above_threshold
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
illuminance_above_threshold is ON, if false
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.