Schneider Electric CCTFR6400
| Model | CCTFR6400 | 
| Vendor | Schneider Electric | 
| Description | Temperature/Humidity measurement with thermostat interface | 
| Exposes | keypad_lockout, humidity, battery, voltage, action, climate (occupied_heating_setpoint, local_temperature, pi_heating_demand), linkquality | 
| Picture | ![]()  | 
    
Notes
Device info
This device is a
- thermostat UI for displaying/adjusting target set point.
 - temperature sensor
 - hygrometry sensor
 
It can display the heating status of associated climate by setting pi_heating_demand
It requires a Z-Stack controller (Firmware version > TBD). It is currently not working with zigate and conbee II (maybe supported in further firmware).
Options
How to use device type specific configuration
- 
    
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 - 
    
temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. - 
    
humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 - 
    
humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. 
Exposes
Keypad_lockout (enum)
Enables/disables physical input on the device.
Value can be found in the published state on the keypad_lockout property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"keypad_lockout": NEW_VALUE}.
The possible values are: unlock, lock1, lock2.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is %.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 100.
The unit of this value is %.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is mV.
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action property.
It’s not possible to read (/get) or write (/set) this value.
The possible values are: screen_sleep, screen_wake, button_press_plus_down, button_press_center_down, button_press_minus_down.
Climate
This climate device supports the following features: occupied_heating_setpoint, local_temperature, pi_heating_demand.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint": VALUE}whereVALUEis the °C between4and30. Reading (/get) this attribute is not possible.pi_heating_demand: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"pi_heating_demand": VALUE}whereVALUEis the % between0and100. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.