Aurora Lighting AU-A1ZB2WDM
Model | AU-A1ZB2WDM |
Vendor | Aurora Lighting |
Description | AOne 250W smart rotary dimmer module |
Exposes | light (state, brightness), effect, power_on_behavior, backlight_led, linkquality |
Picture |
Notes
Pairing
To pair the dimmer, press and hold the knob for 6 seconds. The connected load, and the red LED indicator behind the dimmer knob will flash twice to indicate it has entered pairing mode. The connected load, and the red LED indicator behind the dimmer knob will flash a third time to indicate that it has paired successfully.
Options
How to use device type specific configuration
-
transition
: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to0
(no transition). The value must be a number with a minimum value of0
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
Exposes
Light
This light supports the following features: state
, brightness
.
state
: To control the state publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"state": "ON"}
,{"state": "OFF"}
or{"state": "TOGGLE"}
. To read the state send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"state": ""}
.brightness
: To control the brightness publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"brightness": VALUE}
whereVALUE
is a number between0
and254
. To read the brightness send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"brightness": ""}
.
Transition
For all of the above mentioned features it is possible to do a transition of the value over time. To do this add an additional property transition
to the payload which is the transition time in seconds.
Examples: {"brightness":156,"transition":3}
, {"color_temp":241,"transition":1}
.
Moving/stepping
Instead of setting a value (e.g. brightness) directly it is also possible to:
- move: this will automatically move the value over time, to stop send value
stop
or0
. - step: this will increment/decrement the current value by the given one.
The direction of move and step can be either up or down, provide a negative value to move/step down, a positive value to move/step up.
To do this send a payload like below to zigbee2mqtt/FRIENDLY_NAME/set
NOTE: brightness move/step will stop at the minimum brightness and won’t turn on the light when it’s off. In this case use brightness_move_onoff
/brightness_step_onoff
{
"brightness_move": -40, // Starts moving brightness down at 40 units per second
"brightness_move": 0, // Stop moving brightness
"brightness_step": 40 // Increases brightness by 40
}
Effect (enum)
Triggers an effect on the light (e.g. make light blink for a few seconds).
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"effect": NEW_VALUE}
.
The possible values are: blink
, breathe
, okay
, channel_change
, finish_effect
, stop_effect
.
Power_on_behavior (enum)
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, on
, toggle
, previous
.
Backlight_led (binary)
Enable or disable the blue backlight LED.
Value can be found in the published state on the backlight_led
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"backlight_led": NEW_VALUE}
.
If value equals ON
backlight_led is ON, if OFF
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.