Schneider Electric 545D6306
Model | 545D6306 |
Vendor | Schneider Electric |
Description | LK FUGA Wiser wireless PIR with relay |
Exposes | switch (state), occupancy, illuminance_lux, illuminance, occupancy_timeout, linkquality |
Picture |
Options
How to use device type specific configuration
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Illuminance_lux (numeric)
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It’s not possible to read (/get
) or write (/set
) this value.
Occupancy_timeout (numeric)
Time in seconds after which occupancy is cleared after detecting it.
Value can be found in the published state on the occupancy_timeout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"occupancy_timeout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"occupancy_timeout": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 3600
.
The unit of this value is second
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.