ELKO 4523430
Model | 4523430 |
Vendor | ELKO |
Description | ESH Plus Super TR RF PH |
Exposes | display_text, load, regulator_mode, regulator_time, climate (occupied_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state), sensor, floor_temp, max_floor_temp, mean_power, child_lock, frost_guard, night_switching, linkquality |
Picture |
Notes
Pairing
- Press “arrow up” and “M” simultaneously until “joining” and “pairing” is shown on the ELKO Super TR RF display.
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
Exposes
Display_text (text)
Displayed text on thermostat display (zone). Max 14 characters.
Value can be found in the published state on the display_text
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"display_text": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"display_text": NEW_VALUE}
.
Load (numeric)
Load in W when heating is on (between 0-2000 W). The thermostat uses the value as input to the mean_power calculation..
Value can be found in the published state on the load
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"load": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"load": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 2000
.
The unit of this value is W
.
Regulator_mode (binary)
Device in regulator or thermostat mode..
Value can be found in the published state on the regulator_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"regulator_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"regulator_mode": NEW_VALUE}
.
If value equals regulator
regulator_mode is ON, if thermostat
OFF.
Regulator_time (numeric)
When device is in regulator mode this controls the time between each in/out connection. When device is in thermostat mode this controls the time between each in/out switch when measured temperature is within +-0.5 °C set temperature. Choose a long time for (slow) concrete floors and a short time for (quick) wooden floors..
Value can be found in the published state on the regulator_time
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"regulator_time": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"regulator_time": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 20
.
The unit of this value is min
.
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, local_temperature_calibration
, system_mode
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and50
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). Reading (/get
) this attribute is not possible.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.local_temperature_calibration
: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
The minimal value is-12.8
and the maximum value is12.7
with a step size of0.1
.
Sensor (enum)
Select temperature sensor to use.
Value can be found in the published state on the sensor
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensor": NEW_VALUE}
.
The possible values are: air
, floor
, supervisor_floor
.
Floor_temp (numeric)
Current temperature measured from the floor sensor.
Value can be found in the published state on the floor_temp
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_temp": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is °C
.
Max_floor_temp (numeric)
Set max floor temperature (between 20-35 °C) when “supervisor_floor” is set.
Value can be found in the published state on the max_floor_temp
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_floor_temp": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_floor_temp": NEW_VALUE}
.
The minimal value is 20
and the maximum value is 35
.
The unit of this value is °C
.
Mean_power (numeric)
Reports average power usage last 10 minutes.
Value can be found in the published state on the mean_power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"mean_power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Child_lock (binary)
Enables/disables physical input on the device.
Value can be found in the published state on the child_lock
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"child_lock": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": NEW_VALUE}
.
If value equals lock
child_lock is ON, if unlock
OFF.
Frost_guard (binary)
When frost guard is ON, it is activated when the thermostat is switched OFF with the ON/OFF button.At the same time, the display will fade and the text “Frostsikring x °C” appears in the display and remains until the thermostat is switched on again..
Value can be found in the published state on the frost_guard
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"frost_guard": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"frost_guard": NEW_VALUE}
.
If value equals on
frost_guard is ON, if off
OFF.
Night_switching (binary)
Turn on or off night setting..
Value can be found in the published state on the night_switching
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"night_switching": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"night_switching": NEW_VALUE}
.
If value equals on
night_switching is ON, if off
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.