ELKO 4523430
| Model | 4523430 | 
| Vendor | ELKO | 
| Description | ESH Plus Super TR RF PH | 
| Exposes | display_text, load, regulator_mode, regulator_time, climate (occupied_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state), sensor, floor_temp, max_floor_temp, mean_power, child_lock, frost_guard, night_switching, linkquality | 
| Picture | ![]()  | 
    
Notes
Pairing
- Press “arrow up” and “M” simultaneously until “joining” and “pairing” is shown on the ELKO Super TR RF display.
 
Options
How to use device type specific configuration
thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius,fahrenheit
Exposes
Display_text (text)
Displayed text on thermostat display (zone). Max 14 characters.
Value can be found in the published state on the display_text property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"display_text": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"display_text": NEW_VALUE}.
Load (numeric)
Load in W when heating is on (between 0-2000 W). The thermostat uses the value as input to the mean_power calculation..
Value can be found in the published state on the load property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"load": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"load": NEW_VALUE}.
The minimal value is 0 and the maximum value is 2000.
The unit of this value is W.
Regulator_mode (binary)
Device in regulator or thermostat mode..
Value can be found in the published state on the regulator_mode property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"regulator_mode": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"regulator_mode": NEW_VALUE}.
If value equals regulator regulator_mode is ON, if thermostat OFF.
Regulator_time (numeric)
When device is in regulator mode this controls the time between each in/out connection. When device is in thermostat mode this controls the  time between each in/out switch when measured temperature is within +-0.5 °C set temperature. Choose a long time for (slow) concrete floors and a short time for (quick) wooden floors..
Value can be found in the published state on the regulator_time property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"regulator_time": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"regulator_time": NEW_VALUE}.
The minimal value is 5 and the maximum value is 20.
The unit of this value is min.
Climate
This climate device supports the following features: occupied_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint": VALUE}whereVALUEis the °C between5and50. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"occupied_heating_setpoint": ""}.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": VALUE}whereVALUEis one of:off,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"system_mode": ""}.running_state: The current running state. Possible values are:idle,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"running_state": ""}.local_temperature_calibration: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"local_temperature_calibration": VALUE}.The minimal value is-12.8and the maximum value is12.7with a step size of0.1.
Sensor (enum)
Select temperature sensor to use.
Value can be found in the published state on the sensor property.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sensor": NEW_VALUE}.
The possible values are: air, floor, supervisor_floor.
Floor_temp (numeric)
Current temperature measured from the floor sensor.
Value can be found in the published state on the floor_temp property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"floor_temp": ""}.
It’s not possible to write (/set) this value.
The unit of this value is °C.
Max_floor_temp (numeric)
Set max floor temperature (between 20-35 °C) when “supervisor_floor” is set.
Value can be found in the published state on the max_floor_temp property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"max_floor_temp": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_floor_temp": NEW_VALUE}.
The minimal value is 20 and the maximum value is 35.
The unit of this value is °C.
Mean_power (numeric)
Reports average power usage last 10 minutes.
Value can be found in the published state on the mean_power property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"mean_power": ""}.
It’s not possible to write (/set) this value.
The unit of this value is W.
Child_lock (binary)
Enables/disables physical input on the device.
Value can be found in the published state on the child_lock property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"child_lock": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"child_lock": NEW_VALUE}.
If value equals lock child_lock is ON, if unlock OFF.
Frost_guard (binary)
When frost guard is ON, it is activated when the thermostat is switched OFF with the ON/OFF button.At the same time, the display will fade and the text “Frostsikring x °C” appears in the display and remains until the thermostat is switched on again..
Value can be found in the published state on the frost_guard property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"frost_guard": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"frost_guard": NEW_VALUE}.
If value equals on frost_guard is ON, if off OFF.
Night_switching (binary)
Turn on or off night setting..
Value can be found in the published state on the night_switching property.
To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"night_switching": ""}.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"night_switching": NEW_VALUE}.
If value equals on night_switching is ON, if off OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.