Schneider Electric 41EPBDWCLMZ/354PBDMBTZ
Model | 41EPBDWCLMZ/354PBDMBTZ |
Vendor | Schneider Electric |
Description | Wiser 40/300-Series Module Dimmer |
Exposes | light (state, brightness), ballast_minimum_level, ballast_maximum_level, indicator_mode, linkquality |
Picture |
Options
How to use device type specific configuration
-
transition
: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to0
(no transition). The value must be a number with a minimum value of0
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
Exposes
Light
This light supports the following features: state
, brightness
.
state
: To control the state publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"state": "ON"}
,{"state": "OFF"}
or{"state": "TOGGLE"}
. To read the state send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"state": ""}
.brightness
: To control the brightness publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"brightness": VALUE}
whereVALUE
is a number between0
and254
. To read the brightness send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"brightness": ""}
.
Ballast_minimum_level (numeric)
Specifies the minimum light output of the ballast.
Value can be found in the published state on the ballast_minimum_level
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"ballast_minimum_level": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"ballast_minimum_level": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 254
.
Ballast_maximum_level (numeric)
Specifies the maximum light output of the ballast.
Value can be found in the published state on the ballast_maximum_level
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"ballast_maximum_level": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"ballast_maximum_level": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 254
.
Indicator_mode (enum)
Led Indicator Mode.
Value can be found in the published state on the indicator_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"indicator_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"indicator_mode": NEW_VALUE}
.
The possible values are: consistent_with_load
, reverse_with_load
, always_off
, always_on
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.