Plugwise 158-01
| Model | 158-01 | 
| Vendor | Plugwise | 
| Description | Lisa zone thermostat | 
| Exposes | battery, climate (occupied_heating_setpoint, local_temperature, system_mode), linkquality | 
| Picture | ![]()  | 
    
Options
How to use device type specific configuration
- 
    
thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius,fahrenheit - 
    
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 - 
    
temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. 
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 100.
The unit of this value is %.
Climate
This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint": VALUE}whereVALUEis the °C between5and30. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"occupied_heating_setpoint": ""}.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": VALUE}whereVALUEis one of:off,auto. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"system_mode": ""}.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.